EIB 192

    Specifications

    Specifications

    EIB 192

    EIB 192 F

    EIB 192 M

    Input

    Incremental signals

    1 VPP

    Reference mark

    One or distance-coded1)

    Input frequency

    ≤ 400 kHz

    Electrical connection

    M23 connector, 12-pin

    Cable length

    ≤ 6 m

    Output

    Absolute position values

    EnDat 2.2

    Fanuc Serial Interface

    Mitsubishi High Speed
    Serial Interface

    Order designation

    EnDat 22

    Fanuc 02

    Mit 02-4 / Mit 02-24)

    Electrical connection

    M12, 8-pin

    M23, 17-pin

    M23, 17-pin

    Cable length

    ≤ 100 m2)

    ≤ 20 m3)

    ≤ 20 m3)

    Interpolation

    ≤ 16 384-fold (depending on the encoder)

    Power supply

    5 V ± 5% measured at EIB

    Current consumption

    ≤ 160 mA (without load, without encoder)

    Operating temperature

    Storage temperature

    0 °C to 70 °C

    –30 °C to 70 °C

    Vibration 55 to 2000 Hz
    Shock 11 ms

    100 m/s2 (IEC 60 068-2-6)
    300 m/s2 (IEC 60 068-2-27)

    Degree of protection

    IP 65

    Weight

    Approx. 0.3 kg

    1) Note: For distance-coded reference marks, no direction reversals are permitted during referencing (scanning of two neighboring reference marks)

    2) with HEIDENHAIN cable; supply voltage of 5 V ± 5% at the EIB must be maintained

    3) with HEIDENHAIN cable; IEncoder ≤ 150 mA; greater cable lengths upon request

    4) Mitsu01 upon request